English Reference

Why do multiple parallel cables always have one heating up first?

pic(32)_副本.png

In the actual operation of electrical systems, have you encountered situations where multiple parallel cables have current deviation or shunting?

pic(21)_副本.png

During parallel installation of cables, the actual current capacity is not a simple '1+1=2' relationship. Very likely '1+1=1.5' or even '1+1=1' phenomena may occur!

微信图片_20241225134921.jpg

What exactly is cable current deviation?

In scenarios where multiple cables are used in parallel, ideally, the current in each conductor should be evenly distributed.

企业微信截图_17501329644704.png

However, reality is often not the case. If current distribution among conductors becomes uneven, cable current deviation occurs.

pic(36)_副本.png

What causes multiple parallel cable current deviation or shunting?

Cable current deviation is usually caused by multiple factors: ① Three-phase load imbalance is an important reason. ② Harmonic interference cannot be ignored. ③ Line faults are also factors leading to cable current deviation.

微信图片_20241210151756.jpg

Especially noteworthy is that multiple parallel cables present numerous troubles during installation.

  • If copper lugs are not properly made, such as loose compression of copper lugs, this will not only affect normal cable operation but may also further exacerbate current deviation.

03c93ce8-0444-4a0f-a921-0ef133ab066a.jpg

  • Or if contact surfaces are not properly connected, with oxidation, dirt, and other conditions, contact resistance will change, causing uneven current distribution.

企业微信截图_17243125447572.png

The consequences of current deviation are very serious. Conductors with high current will experience abnormal heating, and conductor heating will accelerate insulation material aging. After insulation aging, its insulation performance will decline, easily causing safety accidents such as leakage, and may even cause short circuits and fires.

b940f6e1-5636-460e-948c-5f42f4f722c3.jpg

Moreover, the more complex the situation with high current, dense wiring, and parallel cables, the more attention current deviation problems require.

微信图片_20250702094015.jpg

How to reduce the probability of current deviation?

To effectively reduce the probability of cable current deviation, high-current flexible busbars are a good solution.

展厅施耐德配电柜1.jpg

High-current flexible busbars have large single conductor current capacity, covering 200-6300A.

湖南长沙光伏并网项目2.png

This characteristic allows them to reduce the number of parallels needed to meet the same power requirements, or even eliminate the need for multiple parallels. Compared to multiple parallel cables, this reduces installation complexity and potential problems.

广州鹏辉储能项目1.jpg

Moreover, the connection method for high-current flexible busbars is more convenient, allowing direct drilling for connections without installing copper lugs.

佛山诗歌新能源光伏项目1.jpg

This not only reduces installation costs and difficulty but also greatly reduces the possibility of current deviation caused by improper copper lug installation or poor contact surface connections.

东莞工业厂房项目3.jpg

Many newly built commercial buildings and industrial plants have adopted high-current flexible busbars in their power distribution systems, with good operational results, greatly improving the safety and stability of electrical systems.

展厅施耐德配电柜3.jpg

If you are interested in electrical knowledge or want to learn more about cable operation and electrical safety, welcome to follow us. We will provide you with more professional and practical electrical knowledge!

侧面 5840x1340x2_副本.png