Data Center Project at a Base in Hangzhou
Back to Projects
Data Center

Data Center Project at a Base in Hangzhou

Confidential

Project Location
Hangzhou, Zhejiang, China
Completion Date
August 2025
Project Scale
N/A
Project Duration
N/A

This project involved a data center facility in Hangzhou where the owner had initially planned to use a four-split cable solution for connecting power cabinets to bus ducts. However, the construction space proved too confined, making cable laying extremely difficult. Yanghua's single-run flexible busbar solution provided sufficient current carrying capacity without the need for additional paralleled assemblies. The compact form factor, high flexibility, and ease of installation enabled efficient deployment within the restricted space. With IP68-rated protection and excellent insulation performance, the busbar solution ensured safe and reliable power distribution throughout the data center.

Project Background & Challenges

The data center's confined construction space made the originally planned four-split cable solution impractical, creating significant difficulties in cable laying and routing between power cabinets and bus ducts.

  • Confined construction space that made traditional multi-cable laying extremely difficult
  • Four-split cable solution required excessive physical space for routing and installation
  • Need for high current carrying capacity without paralleling multiple cable runs
  • Strict insulation and safety requirements for data center power distribution infrastructure

Solution

Yanghua replaced the multi-cable plan with a single-run flexible busbar system that delivered the required current carrying capacity in a compact, highly flexible form factor, enabling straightforward installation within the restricted space while achieving IP68-rated insulation performance.

  • Single flexible busbar run replaced the four-split cable assembly, drastically reducing space requirements
  • Compact busbar profile and high flexibility enabled routing through tight construction spaces that cables could not navigate
  • IP68-rated protection and superior insulation performance ensured safe, reliable data center operation
  • Simplified single-run installation eliminated the complexity and labor associated with paralleling multiple cables

Project Results

Single busbar replaced 4 parallel cable runs
Cable Run Simplification
60% less physical volume vs. cable solution
Installation Space Reduction
IP68-rated, full environmental sealing
Ingress Protection
Significantly reduced vs. multi-cable assembly
Construction Complexity